3D Compliance Minimization¶
This tutorial extends the 2D compliance minimization to a three-dimensional cantilever beam and illustrates how OptiCut leverages MPI parallelism through its dolfinx / PETSc backend.
Problem definition¶
The shape optimization problem is identical in structure to the 2D case. Find the domain \(\Omega \subset \mathbb{R}^3\) that minimizes the compliance functional subject to a volume constraint:
The discretization employs the Cut Finite Element Method (CutFEM) with Ghost Penalty stabilization. The displacement field \(u_h\) is sought on the background mesh \(\mathcal{T}_h\), with integration restricted to the physical sub-domain \(\Omega_h = \{x \mid \phi(x) < 0\}\). The stabilized bilinear form reads:
where \(\mathcal{F}_h^{\Gamma}\) denotes the set of interior facets cut by the interface, \(h_F\) is the local cell diameter, and \(\gamma = 10^{-5}(\mu + \lambda)\) is the Ghost Penalty parameter.
Mesh & MPI Partitioning¶
OptiCut relies on dolfinx’s built-in mesh distribution: when launched with mpirun, the mesh is partitioned into sub-domains using SCOTCH (dolfinx’s default graph partitioner). Each MPI process owns a disjoint subset of cells and the associated DOFs, communicating ghost-layer values via PETSc’s scatter operations.
The figures below show the partition of the 3D cantilever mesh for 2 and 4 MPI processes respectively.
Iterative Solver (GAMG)¶
Direct LU factorization does not scale to large 3D problems due to memory requirements. OptiCut therefore uses the Conjugate Gradient (CG) method preconditioned by PETSc’s Geometric-Algebraic Multigrid (GAMG) solver when the parameter linear_solver amg is set. This is configured as follows:
if parameters.linear_solver == "amg":
self.primal_solver.setType(PETSc.KSP.Type.CG)
self.primal_solver.getPC().setType("gamg")
self.primal_solver.setTolerances(rtol=1e-6)
Implementation¶
Two parameter files are provided for this tutorial:
compliance_3D_coarse.txt: coarse mesh with \(h = 0.1\).compliance_3D.txt: finer mesh with \(h = 0.05\) (54,243 DOFs).
Both are designed to run on a standard workstation without a cluster. The remainder of this section focuses on the finer configuration. The cantilever geometry is a box \([0,2]\times[0,1]\times[0,1]\); the left face is clamped (\(\Gamma_D\)) and a downward traction is applied at the centre of the right face (\(\Gamma_N\)).
cost_func compliance
mesh_case 3D
lx 2
ly 1
lz 1
h 0.05
linear_solver amg
target_constraint 0.4
young_modulus 210000000000
Running in Parallel¶
mpirun -n 2 python3 main.py parameters/compliance_3D.txt
For the present mesh size (54,243 DOFs), 2 processes is the recommended configuration (see performance analysis below).
Results¶
Figure 17 Convergence history: compliance cost function (left axis, blue) and constraint \(C(\Omega)\) (right axis, red) over 600 optimization iterations. The dashed black line marks the satisfied constraint (\(C(\Omega) = 0\)).¶
Post-processing in ParaView:
Open
src/res/results.xdmf.Apply a Contour filter on
ls_funcat isovalue \(\phi=0\) to extract the structural boundary.Apply a Warp By Vector filter on
dispto visualize deformed configurations.
Performance Analysis¶
The table below reports wall-clock times for 600 optimization iterations on the \(h=0.05\) mesh (54,243 DOFs total), measured on a standard 8-core workstation.
Processes |
DOFs / process |
Wall-clock time |
Speedup |
|---|---|---|---|
1 |
54,243 |
5770.90 s (96.18 min) |
1.00× |
2 |
~27,100 |
3765.94 s (62.77 min) |
1.53× |
4 |
~13,560 |
3506.94 s (58.45 min) |
1.64× |
The speedup from 1 to 2 processes (1.53×, parallel efficiency 76.5%) is meaningful but sub-linear. The gain from 2 to 4 processes (1.07×) is negligible. This behaviour is consistent with the known communication-to- computation ratio in domain-decomposition methods: at ~13,500 DOFs per process, the MPI synchronisation overhead — ghost-layer exchanges, global reductions for norm computations, and Krylov communication — becomes comparable to the local solve time. For parallel efficiency to remain acceptable above 4 processes, the mesh size should be increased to maintain at least ~20,000–50,000 DOFs per process.